전화: +8615690122018 E-mail (이메일): [email protected]


How to Maintain and Care for Fin Tubes? - DATANG 핀 튜브 열교환기: 고객의 요구에 맞는 효율적인 열 전달 솔루션.

How to Maintain and Care for Fin Tubes?

The maintenance and care of fin tubes mainly include the following aspects:

‌Clean fins‌: Fin tubes are prone to accumulate dust, smoke and other impurities during use, affecting the heat exchange efficiency. It is very important to clean the fins regularly. You can use compressed air to blow, soft brushes to brush or use special cleaning agents to clean, and be careful to avoid scratching the fin surface with hard objects‌.

‌Check the joints and support structures‌: The joints and support structures between fin tubes are prone to leakage and corrosion. Regularly check the sealing and tightness of the joints. If looseness, leakage or corrosion is found, it should be handled in time. At the same time, check the firmness and wear of the supporting structure, and repair or replace it in time if any problems are found.

‌Anti-corrosion treatment‌: Fin tubes are easily corroded when exposed to high temperature and humid environment for a long time. Anti-corrosion treatment measures can be taken, such as coating anti-corrosion paint on the surface of fin tubes, or using corrosion-resistant materials such as stainless steel to manufacture fin tubes‌.

‌Check the control system‌: The control system of the finned tube is of great significance to ensure the normal operation of the equipment and energy saving and consumption reduction. Regularly check the integrity and accuracy of the control system. If a fault or large error is found, it should be repaired or calibrated in time‌.

‌Internal cleaning‌: For large-diameter finned tube radiators, internal cleaning is also very important. After turning off the heat source, wait for the radiator to cool down, inject cleaning fluid through professional pipe cleaning equipment, flush the scale and impurities on the tube wall, and ensure that the internal pipe is clean and unobstructed‌.

‌Functional testing and maintenance‌: Regularly evaluate the heat dissipation performance of the finned tube, check whether the working pressure and temperature are within the normal range, and adjust or shut down for maintenance in time if abnormalities are found. At the same time, regularly check the sealing of the radiator to ensure that there is no leakage at the connection parts and valves‌.

‌Anti-corrosion and anti-scaling measures‌: Selecting high-quality media and adding anti-scaling agents can slow down the corrosion and scaling of finned tubes. Regularly descale the radiator to ensure that the heat exchange effect is not affected‌.

Maintenance and Preservation of 지느러미 붙은 튜브: Best Practices for Optimal Performance

1. Routine Maintenance Procedures

  • Mechanical Cleaning
    • Weekly dry brushing using nylon-bristle tools (max 0.3mm bristle diameter) along fin direction
    • Compressed air blowing at ≤5 bar pressure for dust removal between fins
    • Prohibited: Metal brushes or high-pressure (>50 bar) water jets that may deform fins
  • Chemical Cleaning

    Deposit TypeCleaning AgentConcentrationTemperatureDurationMineral scaleCitric acid5-10%50-60°C2-4 hrsOrganic filmAlkaline detergentpH 9-1140-50°C1-3 hrsBiological growthSodium hypochlorite100-200ppmAmbient30 min

2. Periodic Inspection Schedule

  • Monthly Checks:
    • Visual inspection for fin damage (≥3% deformation requires correction)
    • Leak testing with 1.5× working pressure (helium detection preferred)
    • Infrared thermography for temperature uniformity analysis
  • Annual Overhaul:
    • Eddy current testing for wall thickness (min. 1.5mm for 304SS tubes)
    • Dye penetrant examination of all welds
    • Coating thickness measurement (min. 120μm for epoxy coatings)

3. Corrosion Prevention Measures

  • Material Selection Guide:

    EnvironmentRecommended MaterialProtection MethodCoastal316L with Ni platingCathodic protection (-0.85V)High-temperature flue gas310SAluminized coatingChemical processingHastelloy C-276PTFE lining

  • Winter Preservation:
    • Drain completely OR fill with inhibited glycol solution (40% vol.)
    • Nitrogen purging for systems >3 months idle (dew point ≤-40°C)

4. Performance Monitoring Parameters

  • Record these metrics quarterly:
    • Pressure drop increase (alert threshold: >15% baseline)
    • Heat transfer coefficient decrease (>20% requires cleaning)
    • Air-side fouling factor (max 0.0005 m²·K/W for HVAC systems)

5. Safety Protocols

  • Lockout-Tagout (LOTO) procedures mandatory before maintenance
    • Double block and bleed for hazardous media
    • Confined space entry permits required for large bundles
  • PPE Requirements:
    • Chemical cleaning: Acid-resistant suits + full-face respirators
    • High-altitude work: Fall arrest systems with 5,000 lb anchors