Tel: +8615690122018     E-mail: [email protected]


Finned Tube Air Cooler Heat Exchanger - DATANG Fin Tube Heat Exchanger: Efficient Heat Transfer Solutions for Your Needs.

Air Cooler/

Finned Tube Air Cooler Heat Exchanger

Subfield Application Scenarios Technical Parameters
Metallurgy Blast furnace waste heat recovery 400°C, 200–1000 kW heat exchange
Food Processing Hot air circulation in drying systems Food-grade coating, pH 3–11 resistance
Pharmaceutical Reactor cooling/sterile temp. control Clean design, surface roughness Ra≤0.8μm

  • Product Details
  • Product Attributes

Finned Tube Air Cooler Heat Exchanger in Refinery

Finned Tube Air Cooler Heat Exchangers, also known as tube-fin air coolers, are a type of heat exchange equipment widely used in heat exchange.

The heat exchange element commonly used in Finned Tube Air Cooler Heat Exchangers is finned tubes. Common base tubes for finned tubes are seamless steel or stainless steel tubes, with common diameters of 25*2, 18*2, and 25*2.5. Common outer diameters for finned tubes include 38, 50, and 57.

The quality, material selection, manufacturing processes, and material specifications of the finned tubes are strictly in accordance with national standards. Finned Tube Air Coolers are generally used in two ways:

1. Cooling the air outside the tubes

A low-temperature medium is passed through the Finned Tube Air Cooler Heat Exchanger. The efficient heat transfer of the finned tubes cools the air, reducing the temperature of the air flowing through the cooler. The lowest air outlet temperature is related to the inlet temperature of the cooling medium (3-5°C higher than the cooling medium temperature).

Air and medium flow in countercurrent. This type of air cooler is primarily designed to cool condensed air. Materials can include steel-aluminum composite, stainless steel, and other materials.

2. Cooling the heat medium within the tube

A finned tube air cooler heat exchanger uses a high-temperature medium (such as hydraulic oil or hot water) to flow through the tubes. A fan forces air through the fins on the outside of the tubes, removing heat from the medium inside the tubes and lowering the medium’s temperature. The outlet temperature of the cooling medium is significantly affected by the ambient air, typically exceeding 5°C.

Finned tube air coolers can be categorized by material: stainless steel air coolers, finned tube air coolers, bimetallic air coolers, and steel-aluminum composite air coolers. By manufacturing process, they can be divided into wound fin air coolers and rolled fin air coolers, among others.

This type of air cooler has a wide range of applications because air is the cheapest cooling medium and is inexhaustible.

Finned Tube Air Cooler Heat Exchanger, also known as tube-fin air cooler, is a widely used heat exchange device.

The heat exchange element commonly used in Finned Tube Air Cooler Heat Exchangers is finned tubes. Common base tubes for finned tubes are seamless steel or stainless steel tubes, with common diameters of 25*2, 18*2, and 25*2.5. Common outer diameters for finned tubes include 38, 50, and 57.

The quality, material selection, manufacturing process, and material specifications of the finned tubes are strictly in accordance with national standards. Finned Tube Air Coolers are generally used in two ways:

1. Cooling the air outside the tubes

A low-temperature medium is passed through the Finned Tube Air Cooler Heat Exchanger. The efficient heat transfer of the finned tubes cools the air, reducing the temperature of the air flowing through the cooler. The lowest air outlet temperature is related to the inlet temperature of the cooling medium (3-5°C higher than the cooling medium temperature).

Air and medium flow in countercurrent. This type of air cooler is primarily designed to cool condensed air. Materials can include steel-aluminum composite, stainless steel, and other materials.

2. Cooling the heat medium within the tube

A finned tube air cooler heat exchanger uses a high-temperature medium (such as hydraulic oil or hot water) to flow through the tubes. A fan forces air through the fins on the outside of the tubes, removing heat from the medium inside the tubes and lowering the medium’s temperature. The outlet temperature of the cooling medium is significantly affected by the ambient air, typically exceeding 5°C.

Finned tube air coolers can be categorized by material: stainless steel air coolers, finned tube air coolers, bimetallic air coolers, and steel-aluminum composite air coolers. By manufacturing process, they can be divided into wound fin air coolers and rolled fin air coolers, among others.

This type of air cooler has a wide range of applications because air is the cheapest cooling medium and is inexhaustible.

Fin Fan Heat Exchanger(Air Exchanger) Specification Parameter Table

Model/Series Heat Transfer Area (m²) Working Pressure (MPa) Operating Temp. (°C) Material Fin Type Application Scenarios
KL-350 350 0.63 ≤100 Aluminum rolled-fin tube Smooth fins Petrochemical, hydraulic system cooling
KL-454 454 0.63 ≤100 Al/Cu-Al composite Serrated fins (ratio ≥12) High-temp. flue gas waste heat recovery
FL-20 20 1.6 ≤100 Carbon steel (galvanized) Spiral fins Construction machinery hydraulic cooling
FL-45 45 1.6 ≤100 Stainless steel 316L Louvered fins Marine platform corrosion-resistant cooling
GP9X2 Series 85–110 4.0–6.4 ≤400 09Cr2AlMo rare-earth alloy L-type rolled fins Petrochemical crack gas high-temp. cooling

Prev:

Next:

Leave a Reply

Copyright © 2024 www.dtfinnedtube.com All Rights Reserved.

Phone +8615690122018

LinkedIn LinkedIn

Skype live:[email protected]

WhatsApp +8615690122018

WeChat QR Code WeChat

QQ 939249279

E-Mail [email protected]

Back to top Back to top

WeChat

WeChat QR Code

Scan the QR Code with WeChat

Leave a message